The working principle of the HO- 4 two-position four-way solenoid valve - Section 4 The start of the control valve 1 unit.

2024-06-20 10:05

4. Signal is given to the control valve 1 alone.

When the air pressure reaches a certain value, the solenoid valve 1 is opened and is supplied with gas independently by the gas path 2.

One-way Valve


When solenoid valve 1 is opened, the control cavity is connected to the gas source, and the control cavity 1 forms a high-pressure cavity. The pressure will push the valve stem to move towards the high-pressure cavity and block the passage for high-pressure gas to enter molecular sieve 1, and molecular sieve 1 exhausts. The red arrow in the figure indicates the direction of high-pressure gas, and the green arrow indicates the direction of the air flow. Due to the reduction of the green air flow, the pressure in the yellow area is less than that in the red area.

In addition, the two other molecular sieves are connected by the purge hole. The compressed gas from molecular sieve 2 will purge and regenerate molecular sieve 1.

When solenoid valve 1 is opened and solenoid valve 2 is closed, molecular sieve 2 pressurizes for oxygen production, and molecular sieve 1 exhausts and regenerates.


Product recommendation.


About us.


Shenyang HOlian Precision instrument co.,Ltd founded in 2017,is specialized production of oxygen generator accessories :Miniature solenoid valve for Portable Medical oxygen generator,4 Way 2 position Medical oxygen generator,3L to 10L Medical Oxygen Generator Solenoid Valve,pressure regulator assembly for oxygen concentrator,Pressure reducing Assembly for oxygen concentrator,Pinhole flowmeter of oxygen concentraror,Pinhole flowmeter of Medical oxygen concentrator,5L flowmeter for oxygen concentrator,Special firesafe Valve for oxygen concentrator,Firesafe Cannula Valve Oxygen Supply Tubing Connector,Oxygen primary filter,Medical Grade Filter,Check valve (material PA6),Check valve (material ABS),Oxygen generator accessories Molecular sieve tank head,Oxygen Concentrator Accessories Air Filters,Oxygen Concentrator Accessories NPT1/8-∅8 Connector,Oxygen Concentrator Accessories NPT1/8-∅10 Connector,Oxygen Concentrator Accessories 3 way Nozzle,Oxygen Concentrator Accessories 90° Nozzle,Mold manufacturing and i jection molding.Pressure Regulator

Get the latest price? We'll respond as soon as possible(within 12 hours)