Introduction: Reasons for the influence of flow rate on oxygen concentration

When the oxygen generator is in the normal working state, the oxygen concentration is stable when it outputs oxygen at the rated flow rate; when the output of oxygen exceeds the rated flow rate, the oxygen concentration decreases, which is easy to understand because it exceeds the oxygen generation capacity; but there is another phenomenon that when the oxygen generator operates at a very low flow rate lower than the rated flow rate, the oxygen concentration also decreases, which is difficult to explain by the oxygen generation capacity.


At present, there is no scientific explanation or conclusion for the phenomenon of reduced oxygen concentration when working at a low flow rate. Personally, it is understood that the low flow rate output leads to an increase in the gas remaining in the molecular sieve container within the rated period. The excess gas saturates the adsorption capacity of the molecular sieve, and some nitrogen overflows, resulting in a decrease in the oxygen concentration.


Therefore, in the hope of ensuring that the oxygen concentration is not troubled by the change of flow rate, the upper flow limit restriction and lower flow compensation of this product will solve this problem.

Working principle process:

1、 Structure Introduction

flowmeter

2、 Intake air, high-pressure area

pinhole

HOlian


When the airflow pipeline is connected to the air intake interface, the position of the red line is the high-pressure area.

3、 Adjust the knob to the required gear.

flowmeter

By rotating the knob to drive the valve stem and the flow plate to rotate, the valve stem is provided with a wavy groove that interacts with the spring positioning mechanism, thereby ensuring the hand feeling of each rotation. When the gear is in place, there will be a slight impact sound and hand feeling to confirm the connection of the gear. The gas path after connection is controlled by the micropores of the flow plate. The flow rate will fluctuate according to the set input pressure. When the set pressure is 45-55 kpa, the output range of the flowmeter is 0.5 to 5 liters, with each 0.5 as a gear.

4、 Low-flow pressure relief

pinhole

The oxygen concentrator has the phenomenon that the oxygen concentration decreases when working at a low flow rate for a long time. The lowest value of this phenomenon is generally 2 liters per minute. That is, during the working process of the oxygen concentrator, the oxygen concentration will not decrease when the flow rate is not lower than 2 liters per minute. Therefore, we need to add pressure relief at the flow rate gears below 2 liters. When the gear is at 0.5 liters per minute, add 2 liters of pressure relief; when the gear is at 1 liter per minute, add 1.5 liters of pressure relief; when the gear is at 1.5 liters per minute, add 1 liter of pressure relief.

5、 Current-limiting disk

HOlian

Core component current-limiting disk: Through thousands of tests and explorations to obtain valid data, along with high-precision injection molding solutions and a strict screening process, it is ensured that the flow deviation of each gear is within ±5% or ±100 ml (take the smaller value between them). Ensure the smooth passage of the flow accuracy test of the oxygen generator.


Product recommendation.

     flowmeterBand gear pinhole flowmeter of oxygen concentrator

     pinholeBand gear pinhole flowmeter of oxygen concentrator with Electronic signal

     HOlianPinhole Flow Meter Of Oxygen Concentrator


About us.

Shenyang HOlian Precision instrument co.,Ltd founded in 2017,is specialized production of oxygen generator accessories :Miniature solenoid valve for Portable Medical oxygen generator,4 Way 2 position Medical oxygen generator,3L to 10L Medical Oxygen Generator Solenoid Valve,pressure regulator assembly for oxygen concentrator,Pressure reducing Assembly for oxygen concentrator,Pinhole flowmeter of oxygen concentraror,Pinhole flowmeter of Medical oxygen concentrator,5L flowmeter for oxygen concentrator,Special firesafe Valve for oxygen concentrator,Firesafe Cannula Valve Oxygen Supply Tubing Connector,Oxygen primary filter,Medical Grade Filter,Check valve (material PA6),Check valve (material ABS),Oxygen generator accessories Molecular sieve tank head,Oxygen Concentrator Accessories Air Filters,Oxygen Concentrator Accessories NPT1/8-∅8 Connector,Oxygen Concentrator Accessories NPT1/8-∅10 Connector,Oxygen Concentrator Accessories 3 way Nozzle,Oxygen Concentrator Accessories 90° Nozzle,Mold manufacturing and i jection molding.

flowmeter

Get the latest price? We'll respond as soon as possible(within 12 hours)